Med-Hycos - les Données

Le Projet

Les Activités

Les Données

Les Logiciels

 


La Méditerranée

L'Histoire de l'Eau

Climat, Météorologie

La mer Méditerranée

L'eau douce

 


Base de connaissance

Recherche

Base de données

Pays

 


   ACCUEIL


Contact


ARNO -
SAN GIOVANNI ALLA VENA
STATION IDENTIFICATION

Country : Italy - Region : Toscana - Municipality : Vico Pisano - Province : Pisa
River Name : Arno - Major Basin : Arno
Station Name : San Giovanni alla Vena - Station Code or number :5190
Coordinates :
43°41' N latitude - 01°52' W longitude (Ref. Monte Mario) and 6.71 m above sea level
Catchment area : 8 186 sq km - Date Station Opened : 1.07.1922

CHANNEL CHARACTERISTICS
Channel Geometry : _____ m width and ____ m depth
with stable / fair / unstable river bed cross-section, underlain by : ___
The river bed is natural / man made : ___
Describe the hydraulic conditions within the measuring station : ___

HYDROLOGICAL REGIME
Natural or influenced flow : natural
with slow rise or flash floods : slow rise
Annual max. and min. mean flow : 2 060; 97.40; 2.20m3/s

EQUIPMENT AND PERSONNEL
Equipment installed and status : the installation is located on the top of a reinforced concrete pier, which is attainable from the river bank by means of a footbridge, also in concrete.
Status : medium
Gauging equipment and status : horizontal hydrometregrapher - manuf. SIAP; electronic station SP 200 - manuf. CAE with differential pressure sensor
Status : good.
Observer or watchman : Observer : Pieroni Maria Granuccia. Station officer : Armaioli Magi Pier Luigi

VOLUME AND QUALITY OF INFORMATION AVAILABLE
DAII : ca. 95 % (Discharge Available Information Index : number of monthes with complete discharge information / number of observed years / 12)
Rating curve status (currently updated or not) : 31.12.1994
Number of discharge measurements (dm) available : ca. 3 measurements / year
Highest water level observed : 8.94 mt - Date : 4.11.1966
Highest water level at which dm taken: ___ - Date : ___
Lowest water level observed : 0.04 mt - Date : 15.8.1931
Data storage medium (computerized or not) : mixed
Data dissemination medium (diskette or hand filled form) : mixed
Status of the database (which data, currently updated or not) : updated

OPERATION AND MAINTENANCE (O & M)
Number of visits currently undertaken per year : 8
Ease of access : easy
Ease of flow measurement (describe) : difficult
Technique(s) used for discharge measurement (wading, bridge, slope area, etc.) : on foot or by cable-way
Equipment used in discharge measurement : current meter
Equipment used in stage measurement : ___
Operation and maintenance budget per annum for the station : 200 000 It. lire

BENEFITS AND INTEREST
Current use of the data and who uses it (describe) : ___
Estimated revenue from use of data (if charges are raised) per annum : ___
Expected future use and where will it be used (describe) :
Additional data needed (which ones) : ___
Real time needed (for what purposes) : already in real time

SERVICE ORGANIZATION
Name : Ufficio Idrografico e Mareografico di Pisa
Organization : Presidenza del Consiglio dei Ministri - Dipartimento per i Servizi Tecnici Nazionali - Servizio Idrografico e Mareografico Nazionale
Address : Lungarno Pacinotti 49 - Pisa
Number of staff : 15

Form filled by :
Title :
Date :
Address :

DCP INSTALLATION



Name                                      ITALY/HYCOS1
Meteosat Identification Code     16A87628
Frequency Channel                  R31
Frequency                               402.1915 MHz
First Time Emission                 01.00.00
Emission Interval                      3 h
________________________________

EQUIPMENT :

DCP of CAE Manufacturer

_________________________________

SITE :

San Giovanni 43°41 N  10°35 E
N° OMM =  16156 
First data in April 2000