Med-Hycos - les Données

Le Projet

Les Activités

Les Données

Les Logiciels

 


La Méditerranée

L'Histoire de l'Eau

Climat, Météorologie

La mer Méditerranée

L'eau douce

 


Base de connaissance

Recherche

Base de données

Pays

 


   ACCUEIL


Contact


VARDAR A SKOPJE
STATION IDENTIFICATION

Country :R. Macedonia - River Name :Vardar - Major Basin :Agean Sea
Station Name :Skopje - Station Code or number :13588
Coordinates : 41°59'44" N latitude - 21°26'50" E longitude and 242,56 m above sea level
Catchment area : 4650 sq km - Date Station Opened : from 1954

CHANNEL CHARACTERISTICS
Channel Geometry : 51 m width and 1,5 m depth
with stable river bed cross-section, underlain by :
The river bed is man made, double river bed (major and minor)
Describe the hydraulic conditions within the measuring station : Non inundation, J=0,1

HYDROLOGICAL REGIME
mostly natural flow with flash floods
Annual max. and min. mean flow : max 76,8, min 22,7 m3/s

EQUIPMENT AND PERSONNEL
Equipment installed and status : water level recorder
Gauging equipment and status : current meter
Observer or watchman : observer

VOLUME AND QUALITY OF INFORMATION AVAILABLE
DAII : 50 years (Discharge Available Information Index : number of monthes with complete discharge information / number of observed years / 12)
Rating curve status (currently updated or not) : currently updated
Number of discharge measurements (dm) available : 350
Highest water level observed : 499 cm - Date : November 1962
Highest water level at which dm taken : 264 cm - Date : November 1962
Lowest water level observed : 22 cm - Date : August 1990
Data storage medium (computerized or not) : computerized
Data dissemination medium : diskette
Status of the database (which data, currently updated or not) : currently updated

OPERATION AND MAINTENANCE (O & M)
Number of visits currently undertaken per year : 6 to 8 per year
Ease of access : easy
Ease of flow measurement (describe) : Measurements for minimum and mean flows are carried out easily but for maximum, difficulty to measure
Technique(s) used for discharge measurement (wading, bridge, slope area, etc.) : wading, boat, bridge
Equipment used in discharge measurement : hand winch, current meter, etc
Equipment used in stage measurement : Equipment for suspended sediments
Operation and maintenance budget per annum for the station : 3000 US$

BENEFITS AND INTEREST
Current use of the data and who uses it (describe) : - internal usage for the necessities of economy - water management - and other users
Estimated revenue from use of data (if charges are raised) per annum : As a budget institution we do not make estimation
Expected future use and where will it be used (describe) : Interest for future use of data is raising continuously especialy in water management
Additional data needed (which ones) : ____
Real time needed (for what purposes) : - 15 minutes for measurements of PH - 1 hour for measurements of total sediment for purposes of the fast water quality control - 2 hours for the measurements of flow

SERVICE ORGANIZATION
Name : Hidrological Department
Organization : Republic Hydromoeteorological Institute
Address : Skupi b.b 91 000 Skopje, Republic of Macedonia
Number of staff : 37
Form filled by : Josif Milevski
Title : Hydrologist
Date : 03 IX 1996

DCP INSTALLATION






Name                                      : MACEDON/HYCOS1
Meteosat Identification Code     : 16E5C51C
Frequency Channel                  : R09
Frequency                               : 402.1255 MHz
First Emission Time                 : 01.16.30
Emission Interval                     : 3 h
________________________________

EQUIPMENT :

DCP PM46 V3.3 n° 96024
Meteosat Transmitter with GPS Receiver
Antenna YAGI
Memory Card 1 Mo n°105 et n°110
Battery 12V / 26Ah
Solar Panel 12V / 20W
Temperature & Level Water Probe CCI n°5222 with 30 m adding cable
Air Temperature PT100 with shelter n° 3153
Raingauge 400 cm2 Precis Mecanique 3030
_________________________________

SITE :

Zajcev Rid : 42°00 N  21°24 E
N° OMM = 13588
Send August 97
Installed April 2000